General electric zoneline manual. GE Zoneline PTAC Units 2019-02-28

General electric zoneline manual Rating: 5,5/10 1866 reviews

GE Zoneline PTAC Units

general electric zoneline manual

And thanks to electronic temperature limiting built into the unit, you can easily preset temperature limits to save energy to balance guest comfort with an efficient operation. Devi Summary of the content on the page No. Review the charts on the following pages first and you may not need to call for service. A separate wire pair must be run from each separate controlling switch to each individual Zonelin Summary of the content on the page No. Limited 5-year sealed refrigerating system Labor Warranty Limited 1-year entire appliance. A test and reset button is provided on the plug case or 1 Remove the room cabinet. The Freeze Sentinel and Heat Sentinel protect against extreme heat or cold conditions should the room get too cold or hot.

Next

GE Zoneline PTAC Units

general electric zoneline manual

If you want to quickly view the content of pages found on the following pages of the manual, you can use them. For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. Be sure to include all of the information listed below to receive the most accurate information. The owner is responsible for checking switches and ensuring they are in the desired position. Having two separate motors for each fan reduces noise by dialing in the exact airflow needed for each heating and cooling function, instead of having one fan run faster and more often to manage the same output.

Next

GE Zoneline Replacement Parts, Page 3

general electric zoneline manual

The most common installation of this type of system is a 20 900 Ft. These sentinels are further complimented by a Reverse Cycle Defrost which allows the unit to run in heat pump mode longer, saving you energy and money. Zonelines are designed for quiet operation with low sound levels and low sound transmission. Clogged filters reduce cooling, heating and air flow. See the Install Summary of the content on the page No. If you want to quickly view the content of pages found on the following pages of the manual, you can use them. To maintain optimum performance, clean the filters at least every 30 days.

Next

GE Zoneline PTAC Units

general electric zoneline manual

The barrier is complimented by a Weather Barrier System Seal which lines the perimeter of the unit to keep noise and dirt outside, performing optimally near high traffic areas. See Zonel Summary of the content on the page No. R ecommended wire size must be followed as a minimum to operate from a control device remote to the unit or even requirement. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. This model is equipped with Internal Condensate Removal, suited perfectly for humid regions to keep the unit running optimally at all times. Plugging this unit into a branch circuit wiring inside the provided junction box building mounted exposed receptacle is not permitted must be done in accordance with the following steps. Optimal efficiency is attained by means of the many features integrated within the unit to specifically avoid excessive temperature swings.

Next

GE ZONELINE 4100 OWNER'S MANUAL Pdf Download.

general electric zoneline manual

External Fan Obtained locally When connected, an auxiliary or external fan can be controlled with the indoor fan motor on the Zoneline. Heat Pump with Resistance Heat Backup. It is important that any air mounted high in the wall, the conditioning system be properly sized and applied in order discharge louvers should be to achieve the desired temperature and humidity levels with at a setting that provides the the space to be conditioned. For example, this unit comes equipped with heat and freeze sentinels, specially designed to protect your property by preventing overheating or freezing of the unit. There may be multiple blocks and pieces properly installed per instructions packed with of shipping tape that need to be removed. The device should be tested on a 2 Connect to electrical power. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.

Next

GE Zoneline

general electric zoneline manual

Advertisement Print version Many people prefer to read the documents not on the screen, but in the printed version. This will reduce the heating or cooling efficiency. Note how the tabs on the lower conduit and bring wires into the junction box. When set at the open position, some outdoor air will be drawn into the room. . Summary of the content on the page No.

Next

GE Zoneline

general electric zoneline manual

However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase. Do not use bleach or abrasives. Heat Pump with Supplemental Resistance Heat. Turn the Zoneline off before cleaning. Since more moisture will be removed from the air, there is a greater possibility that water will drip from the wall case than with a standard unit. A rustproof base pan comes standard on all models, along with a service diagnostics port so technicians can quickly diagnose unit issues. Use the slit in the outdoo Summary of the content on the page No.

Next

GE ZONELINE 4100 OWNER'S MANUAL Pdf Download.

general electric zoneline manual

See the To Remove the Room Cabinet section. In fact, its extensive Heat Source Logic ensures the unit is running from the most efficient heat source at all times to cost-effectively meet guest needs. The Heat sources: Heat pump, heat pump and simultaneous full heat output of the resistance heater is dependent upon electric resistance heat or electric resistance heat. Use of components not specifically designed or approved for use with the Zoneline can result in unsatisfactory op Summary of the content on the page No. Some installations may use a sub-base for support of the unit or for ease of electrical connections. Outdoor Coils The coils on the outdoor side of the Zoneline should be checked regularly. The room air will be filtered and Vent Close Summary of the content on the page No.

Next

GE Zoneline 2900 user manual

general electric zoneline manual

Outdoor Vent Control — 3 Positions Temperature Limiting Electronic 7-Step Sensible Heat Ratio 70% Control Type Standard Microcomputer. The Zoneline has been given an updated look, with a sleek appearance that features a shallower depth for more usable room space. Remove the knockout, attach the 2 Remove the junction box by removing the top and bottom rear screws. Advertisement Print version Many people prefer to read the documents not on the screen, but in the printed version. Zonelines are also compatible with central desk control systems. When set at the closed position, only the air inside the room is circulated and filtered. Summary of the content on the page No.

Next